Parallel control
Full control of up to 12 Biobook systems in parallel
Two vessels, fully independent control. The Biobook Twin brings parallel process development to the bench: two 350 mL to 40 L vessels with independent temperature, agitation, gas and pumps, and Bioflex™ SCADA software networking up to 24 reactors.
On each module, the gauges monitor the pressure of the four gases (air, O₂, CO₂ and N₂) regulated by the thermal MFCs, with flow rates from 0.002 to 20 L/min.
Four pumps per vessel, expandable to eight: 0.05 to 50–100 mL/min, reversible flow and manual, timed or gravimetric mode.
Sparger and overlay lines for mixed gases, controlled by Bioflex™. Aeration strategies: 4-gas mixing, DO cascade, O₂/N₂ enrichment and CO₂/pH control.
START button to start the system.
STOP emergency button on the sealed front panel (IP21 protection rating).
The lower module repeats the gauges, pumps and sparger and overlay lines: the two vessels are controlled fully independently.
On the upper module, four connectors for ISM / ARC digital probes: glass (2–12) or optical (6.5–8.5) pH, dissolved oxygen and pCO₂ (optional).
On the upper module, four 4–20 mA connectors for analog sensors and instruments, such as Pt100 temperature, gas analyzer and more.
On the lower module, RJ45 ports for the Bioflex™ SCADA software (up to 24 bioreactors, independent or linked; OPC UA, Modbus TCP, Ethernet/IP and optional Profibus) and a USB 2.0 port to update the firmware.
On the upper module, RJ45 ports for secure remote control of Bioflex™ via browser or VPN and a USB 2.0 port to update the firmware.
On the lower module, four connectors for ISM / ARC digital probes.
On the lower module, four 4–20 mA connectors for analog sensors and instruments, such as Pt100 temperature, gas analyzer and more.
One inlet per module: 100–240 V AC, 50/60 Hz, single phase; 4 kVA maximum power.
Connectors for the heating blanket and the level and antifoam sensor.
Connectors for mixer power and control parameters.
Connector for the thermochiller and connector for up to 3 scales.
Connection for an additional peristaltic pump module.
Connection for an additional vessel thermostating unit (Wet).
Air, O₂, CO₂ and N₂ on each module: four standard lines per vessel, plus four optional ones. Clean, oil-free compressed air at 3–6 barg.
Inlet and outlet for gas analysis.
Inlet from the chiller or thermochiller and outlets to the condenser and cold finger.
Predictive alerts & automation
Always available
Full SCADA integration
Proactive maintenance
PDF · free registration required.
Same vessel range as the Biobook Compact, mountable on either of the two vessels independently.

Borosilicate with a 316L stainless steel headplate, jacketed or single-wall, with Rushton or pitched impellers.

Electropolished 316L stainless steel, pressure up to 2 barg, with a CIP/SIP option.

Medical-grade PMMA vessel, pre-assembled and pre-sterilized, with pre-calibrated single-use sensors and pre-mounted tubing.

Circulation driven by the injected gas, with no impeller: gentle, ultra-low-shear mixing with even oxygen distribution.
Key differences between the two Biobook control unit models.
| Parameter | Compact | Twin |
|---|---|---|
| Controlled vessels | 1 | 2 (independent) |
| Dimensions (W×D×H) | 341×554×253 mm | 341×554×506 mm |
| Weight | 25.2 kg | 51 kg |
| Power consumption | Max 2 kVA | Max 4 kVA |
| Standard gas lines | 4 + 2 optional | 2× 4 + 4 optional |
| Peristaltic pumps | 4 (expandable to 8) | 4 per vessel (expandable to 8 per vessel) |






The accessories are also compatible with pilot and industrial systems.
Technical documents in PDF · the datasheets ask for a free registration, the catalogues download without one.
The Twin has two independent vessels instead of one, with fully separate temperature, agitation, gas and pump control per vessel. Same width and depth as the Compact but double the height (506 mm vs 253 mm) and nearly double the weight (51 kg vs 25.2 kg).
Yes. The two vessels are fully independently controlled — temperature, agitation, gas, pumps and sensors — making the Twin ideal for A/B comparative studies or parallel process development.
Up to 24 bioreactors, independent or linked, via Ethernet or OPC network, with synchronized data logging across all units — double the Biobook Compact standalone limit (12).
The same range as the Biobook Compact, 350 mL to 40 L total volume: autoclavable glass (0.5 to 12 L), autoclavable stainless steel (1 to 15 L), single-use (0.35 to 40 L) and airlift (0.5 to 12 L), independently mountable on each of the two vessels.